High-Frequency Audiometer.
Boothless High-Frequency Audiometry Anywhere
High-frequency Audiometer
A portable high-frequency audiometer featuring booth-free operation and high frequency hearing testing up to 16 kHz as well as all the diagnostic tools you need. Making the KUDUwave Pro the ideal solution for ototoxicity monitoring programs and audiology practices alike.
The KUDUwave Pro combines the sound booth, audiometers, bone conductor, and extended high-frequency headset in a single, lightweight device.
It includes the full battery of testing options as well as the ability to test almost anywhere.
With KUDUwave boothless audiometers you can now test patients in their homes, hospital beds or at their place of work without compromising on the quality of testing and without having to transport maintain an audiometric booth. Especially useful where the soundbooth could be a source of cross contamination and open air testing is required.
This makes the KUDUwave™ Pro the ideal solution for high-frequency audiometry such as hearing conservation programs, audiology practices, and ototoxicity monitoring programs alike.
The ultimate in clinical audiology and high-frequency audiometry.
FDA Listed, Calibrated to ANSI S3.6, OSHA & SANS 10154-1 & 2 Compliant
It Gets Even Better
Everything you expect and more
Thinking Out Of The Booth
What boothless testing really means.
Passive Attenuation is provided by the unique combination of dual circumaural ear cups and insert earphones, and offers the same level of attenuation as a standard audiometric booth.
Active Noise Monitoring is an additional assurance against intermittent peaks in noise. During a hearing test, ambient sound is monitored by integrated external microphones in real-time. This is simultaneously compared to the intensity and frequency of the tone being presented.
If noise will affect the tone presented it is marked and displayed on the live audiogram view. The clinician is then able to pause testing until the noise subsides or manually repeat the tone later in the test. Noise levels will also be indicated on the final report as a quality control measure.
In automatic test mode, affected tones can be set to repeat later in the test automatically to ensure that every tone is heard.
Don’t Just take our word for it
Hear it from someone who already knows and loves the KUDUwave
Let’s Get Technical
Don’t stress, you can download the datasheet and read through it later
Download The Datasheet
KUDUwave™ Pro Features
- High-Frequency (up to16Khz)
- Boothless Testing
- Active Noise Monitoring
- Talk Forward
- Automated and Manual Testing Protocols (Customisable)
- Patient compliance monitoring
- Integrated speech audiometry (SD, SRT)
- Telemedicine Enabled
- Intuitive PC Based operation (Touchscreen compatible)
- Patient Management and Medical Record Storage
- Print, export or email custom branded results
- Custom Branded Patient Reports
- Automatic interpretations
- Manual tone threshold testing (Air, Bone, Masking, MCL, UCL)
- Automatic diagnostic tone thresholds testing (Air, Bone, Masking)
- Pure Tone Air Conduction
- Bone Conduction
- Automated threshold seeking
- Stenger
- Modified Hughson and Westlake
- Forehead bone conduction maximum 70 dBHL in midrange frequencies
- Narrowband noise masking
- Automatic non-test ear masking for air and bone conduction